PC 1500 Specs:
- 1500 cranking amps for 5 seconds
- 1280 cranking amps for 10 seconds
- 1170 cranking amps for 20 seconds
- 1100 cranking amps for 30 seconds
- Short circuit current over 5000A
- Absorbent glass mat (AGM) technology
- 12V battery pure lead VRLA
- BCI Group 34 footprint - dual purpose
- BCI Group 34/78 footprint - dual purpose
- Rugged construction
- Can be mounted in any orientation except inverted.
- Lifting handle
- US DOT and IATA certified non-spillable
- Shipped fully charged - just install and go!
- Container and cover made from oil resistant plastic
| Performance features:
- PHCA: 1,500 at 80°F (27°C)
- CCA: 880A at 0°F (-18°C)
- CA/MCA: 1,050 at 32°F (0°C)
- HCA: 1,250A at 80°F (27°C)
- Reserve capacity: 135 minutes
- Short circuit current: 3,100A
- Deep cycling capability: 400 at 80% DOD
- Design life: 12 years
- Typical service life: 6 to 8 years
- Operation temperature range: -40°F
(-40°C) to 176°F (80°C)
|
| PC1500DT 34/78-PC1500
Group 34/78 SAE top terminals and 3/8" x 16 female receptacle side
For more information
|
All information and photos are proprietary owned by Kodiak Industries Inc. You may not copy or reproduce without permission
|
ODYSSEY® PC 1500 performance data at 25°C, per 12V module
Time to 10.02v
|
Time |
Watts (W) |
Amps (A) |
Capacity (AH) |
Energy (WH) |
2 min. |
5228 |
494.8 |
16.3 |
172.5 |
5 min. |
3337 |
304.4 |
25.3 |
277.0 |
10 min. |
2175 |
193.6 |
32.3 |
363.3 |
15 min. |
1644 |
144.5 |
36.1 |
411.0 |
20 min. |
1332 |
116.1 |
38.7 |
443.7 |
30 min. |
977 |
84.2 |
42.1 |
488.4 |
45 min. |
706 |
60.3 |
45.2 |
529.3 |
1 hour |
556 |
47.3 |
47.3 |
556.2 |
2 hour |
307 |
25.9 |
51.7 |
615.0 |
3 hour |
215 |
18.1 |
54.2 |
646.5 |
4 hour |
167 |
14.0 |
56.0 |
668.4 |
5 hour |
137 |
11.5 |
57.4 |
685.4 |
8 hour |
90 |
7.6 |
60.6 |
723.1 |
10 hour |
74 |
6.2 |
62.3 |
742.5 |
20 hour |
41 |
3.25 |
65.0 |
814.0 |
|
|